>>Baker Home
>>Offline/Online Products

>>Motor QC Products

>>Support
D30R D40R Surge/HiPot Resistance Tester
Overview and Specifications
   

>>Printable PDF-D30R

>>Printable PDF-D40R

      >>Contact Us
Products & Services
>>Offline/Online Products
>>Motor QC Products
>>Accessories
>>Used Equipment
>>Seminars/Training



How to Buy:
To purchase, contact your local Baker Sales Representative.

   

>>How to Buy

>>Support
>>Downloads


Overview

The D30R/D40R is a high performance stand alone impulse generator specifically designed to diagnose faults in very large electrical motors and windings, improving quality in the shop and reducing necessary and costly downtime in the field. The 30-40kV output allows you to thoroughly test larger windings with lower impedance and higher capacitance. The D30R/D40R satisfies the requirements of testing the windings of both AC motors and DC armatures by producing a Surge with higher voltage and instantaneous current.

  • The D30R/D40R offers you all of the convenient features of digital technology. It performs Resistance, DC HiPot and Surge tests along with incorporating a supply monitor to insure safe operation from a well grounded supply. Additional safety features include a front panel emergency stop switch, zero-start interlock, and a test conclusion forced ground relay on output leads. The control and display module provides the user with comprehensive testing results.
  • The Resistance Test verifies the existence of dead shorts within the turn-to-turn coils, shows any imbalances between phases due to turn count differences, along with locating poor wire connections or contacts.
  • The DC HiPot test can also be done in the D30R/D40R. Test voltage is set by the output control from 500-30000 for the D30R and 500-40000 for the D40R. Current is displayed and an overcurrent trip circuit monitors the test. If current exceeds the trip level, the test is automatically halted. In its most sensitive setting, the protective circuit will operate as low as 10 micro amps.
  • The Surge Test's voltage rise time is 100-200 nanoseconds, so the D30R & D40R comply with IEEE Standard 522-1992 and IEC Standard 34-15 when testing motor windings and coils.
  • The D30R/D40R is housed in a mobile case with the control unit permanently affixed to the upper face. 60kV high voltage test leads are provided along with dedicated Kelvin Resistance Test leads for convenient portable testing. These features along with the unsurpassed testing capabilities make the D30R/D40R powerful and technically advanced for in house shop or field environments.
 
 
 
 
 
 
 
 

 

Specifications

 

 
Surge Test
D30R
D40R
Output Voltage
0-30000V
0-40000V
Max Output Current
1800-2000 amps
2700 amps
Max Pulse Energy (joules)
45
120
Discharge Capacitance
.1µF
..15µF
DC High Potential Test
Max Output Voltage
0-30000V
0-40000V
Max Output Current
1000mA
1000mA
Max Overcurrent Trip
10/100/1000mA
10/100/1000mA
Current Resolution
/1/10/100mA/Div
/1/10/100mA/Div
Resistance Test
.0008Ω-216Ω
.008Ω-216Ω
Physical Characteristics
Weight
290 lbs
305lbs
Dimensions (WxHXD)
24" x 55" x 26"
24" x 55" x 26"
Input Power
110V/220V Single Phase
1000 Watts 50/60Hz
110V/220V Single Phase
1000 Watts50/60Hz

 

Baker Instrument Company, an SKF Group Company
4812 McMurry Avenue Fort Collins, CO 80525
970/282-1200 - 970/282-1010 FAX - 800/752-8272
©Copyright 2007, All Rights Reserved